tel: +86 15153112367 E-mail: [email protected]

Di Contatto |

Commonvocabularyforozonegeneratorselection

Notizie aziendali

Vocabolario comune per la selezione del generatore di ozono

In the daily use of generatore di ozono, incontreremo alcune parole professionali sulla selezione del prodotto del generatore di ozono, Ozono MAX secondo i termini professionali comunemente usati, summary and share with you.
1, ozono: a temperatura e pressione normali è un gas dall'odore azzurro, la formula molecolare è O 3, with strong oxidation capacity and sterilization performance.
2, ozone production: that is, ozone production rate, the amount of ozone generation in hours. Unit of measurement: mg/h, g/h, kg/h. Concentration × flow ≈ yield
3, ozone concentration: the content of ozone per unit volume. Unit of measurement: mg/l, mg/m 3, ppm
4, water-soluble ozone concentration: ozone dissolved in water, ozone content per unit volume. Unit of measurement: mg/l, ppm
5, air application ozone concentration: ozone concentration for air disinfection, generally in 1-10 mg/m 3.
6, environmental ozone concentration: the concentration of ozone contained in the ambient air, the environmental quality standards of the first, second and third levels of environmental quality standards are 0.12/0.16/0.2 mg/m 3.
7, power consumption: does not include the air treatment system, the ozone generator host every 1kg
Electricity consumption by ozone. (The unit is an indicator to evaluate the performance of the generatore di ozono, which is different from the power of the equipment). Unit of measurement: kw · h/kgO3

  1. Dosage: The amount of ozone added to a certain unit of liquid or gas. Unit of measurement: g/m 3, g/T
    9, the output per unit discharge area: the amount of ozone generated in the unit area of the discharge medium, the index is an indicator to evaluate the performance of the discharge medium. Unit of measurement: g/m 3
    10, dew point: the index of air dryness, at what temperature the air begins to appear dew phenomenon. Unit of measurement: ℃.
  2. Intake flow rate: the amount of raw material gas entering the ozone generator discharge chamber per hour. Unit of measurement: m 3 / h
    12, gas discharge flow: from the generator discharge chamber per hour discharge of ozonized gas mixture flow. Unit of measurement: m 3 / h
  3. Intake pressure: the pressure of the raw material gas entering the ozone generator discharge chamber. Unit of measurement: MPa
    14, photochemical ozone generation method: the use of ultraviolet light to decompose oxygen molecules and polymerization to produce ozone method.
    15, electrochemical ozone generation method: The use of DC power supply electrolytes to produce ozone method.
    16, corona discharge method: The use of alternating high voltage electric field to produce corona discharge of oxygen-containing gas, high-energy free electrons in the corona dissociate oxygen molecules and polymerization to produce ozone molecules method.
    17, air gap discharge method: a corona discharge, the discharge area occurs in the dielectric layer and the area between the high voltage electrode or low voltage electrode.
    18, along the surface discharge method: a corona discharge, the discharge area occurs at the edge of the high-voltage electrode.
    19, DTA discharge body: an enamel as the main dielectric ozone discharge body, with high output, high concentration characteristics.
    20, electrode: with a medium with different conductivity to form a conductive interface of the conductive part, in the ozone generation unit distribution of high-voltage electric field of the conductive body.
    21, dielectric tube (plate) : the basic electromagnetic field performance is a component of the material polarized by the electric field, in the ozone generation unit refers to the insulator located between the poles, causing stable glow discharge.
    22, dielectric strength: dielectric material can withstand the highest electric field strength without being destroyed.
    23, glow discharge: when the electric field intensity exceeds a certain value, the electrical conduction phenomenon in the gas shown by luminescence.
    24, ozone generation unit: composed of the most basic components of ozone generation, such as corona air gap discharge ozone generation unit for high voltage electrode, ground electrode, medio, air gap.
    25, tubular ozone generation unit: glow discharge element with concentric circle arranged ozone generation unit.
    26, plate ozone generation unit: glow discharge element to parallel plate arranged ozone generation unit.

Prec:

Prossimo:

lascia un commento

Lasciate un messaggio